S □ -M Series Oil Immersed Power Transformer

Short Description:

The S □ -M series three-phase oil immersed transformer produced by the company adopts full oil filled and sealed corrugated oil tank. The oil tank shell adapts to the oil expansion performance with its own elasticity and meets the heat dissipation requirements.


Product Detail

Product Tags

Product introduction

The S □ -M series three-phase oil immersed transformer produced by the company adopts full oil filled and sealed corrugated oil tank. The oil tank shell adapts to the oil expansion performance with its own elasticity and meets the heat dissipation requirements.
The body adopts a new insulation structure to improve the short-circuit resistance; the core is made of high-quality cold-rolled silicon steel sheet; the high-voltage and low-voltage windings are made of oxygen free copper wires and adopt multi-layer cylindrical structure; all fasteners adopt special anti-loosening treatment.
The product has the characteristics of high efficiency and low loss, can save a lot of power consumption and operating costs, and has significant social benefits. It has been widely used in power plants, substations, industrial and mining enterprises, ports, airports and other places.

Model Meaning

TYPE TRANSFORMER

Standards

GB/T 1094.1-2013 Power transformers - Part 1: General
GB/T 1094.2-2013 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
GB/T 1094.3-2017 Power transformers - Part 3:Insulation levels, dielectric tests and external clearances in air
GB/T 1094.5-2008 Power transformers - Part 5: Ability to withstand short circuit
GB/T 1094.10-2003 Power transformers--Part 10: Determination of sound levels
IEC60076-1:2011 Power transformers - Part 1: General
IEC60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 60076-3:2013+AMD1:2018 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels

Normal Environment conditions

1.Ambient Temperature: No more than +40℃
No less than -25℃
The monthly average temperature is no more than +30℃
The yearly average temperature is no more than +20℃
2.Altitude: No more than 1000m.
3.The power supply voltage's wave is similar to sine wave.
4.Three-phase power supply voltage is approximately symmetrical.
5.The total harmonic content of load current shall not exceed 5% of ratedcurrent;
6.Installation Site: Indoor or outdoor.

Product characteristics

1. The iron core is made of silicon steel sheet with high quality, high performance and high magnetic conductivity, with low no-load
loss.
2. High voltage winding adopts layer structure. Low voltage winding 500KVA and below is layer type, 630kVA and above products
adopt new spiral type. High mechanical strength, balanced ampere turn distribution, strong short circuit resistance.
3. The positioning structure is added to the body to avoid displacement during transportation. At the same time, all fasteners are
equipped with fastening nuts to ensure that the fasteners are not loose during long-term operation.
4. This product is a fully sealed structure. The vacuum oil filling process is adopted when the transformer is packaged, which
completely removes the moisture in the transformer, ensures the isolation of the transformer oil from the outside air, prevents
the aging of the oil, and improves the operation reliability of the transformer. The product is equipped with pressure relief valve,
signal thermometer, gas relay and so on to ensure the safe operation of the transformer.
5. Corrugated oil tank is adopted. This kind of oil tank has the advantages of simple process, high mechanical strength, good welding
effect and no leakage. And because of the strong fluidity of the oil, the heat dissipation capacity of the product is improved.
6. The product is beautiful in appearance, small in volume and small in floor area. It is an ideal maintenance free product.

Transformer Product Selection (29)

S11-M Technical Parameter

caRpaatecdity (kvA) Voltage combination Cognrnoeucpted label diNssoi-ploaatidon (w) dissLiopaadtion (W)75℃ Ncuor-rIoeandt (%) Imvpoeltdaagnece (%)

ExteIrniostraslilz4e-(ΦLx1W8 xH) (mm)

690 510 920

WTeoitgahlt (kg)
High(kvVo)ltage Tarapnpgineg Low(vkoVl)tage

30 50

100 130

630/600 910/870

1.5 1.3

275 340

730

510

960

63

150

1090/1040

1.2

750

550

1000

385

80

180

1310/1250

1.2

790

620

1020

450

100

200

1580/1500

1.1

790

700

1040

520

125

DYyynn101 Yzn11 240

1890/1800

1.1

840

800

1070

625

160

280

2310/2200

1.0

4.0

1070

670

1130

695

200

66.3 61.06 1101.5

340

2730/2600

1.0

1140

750

1140

795

250

400

3200/3050

0.9

1200

800

1190

955

315

±±2x52.5

0.4

480

3830/3650

0.9

1300

860

1210

1085

400

570

4520/4300

0.8

1380

900

1240

1290

500

680

5410/5100

0.8

1450

950

1300

1590

630

810

6200

0.6

1500

970

1360

1850

800

 DYyynn101 980

7500

0.6

 4.5

1660

1140

1400

2210

1000

1150

10300

0.6

1690

1190

1530

2570

1250

1360

12000

0.5

1760

1230

1600

3115

1600

1640

14500

0.5

1800

1250

1660

3520

2000

1940

18300

0.4

1930

1360

1490

4060

2500

2290

21200

0.4

5

2080

1360

1570

5105

Note 1 : for transformers wlth rated capacity of 500kVA and below, the load loss values above the diagonal line in the table are applicable to the Dyn11 or Yzn11 coupling group,and the load loss values below the diagonal line are applicable to the Yyn0 coupling group.
Note 2: when the average annual load rate of the transformer is between 35% and 40%, the maximum operating efficiency can be obtained by using the loss value in the table.

Dimensions

Transformer Product Selection (89)

S13-M Technical Parameter

caRpaatecdity (kvA) Voltage combination Cognrnoeucpted label diNssoi-ploaatidon (w) dissLiopaadtion (W)145℃ Ncuor-rIoeandt (%) Imvpoeltdaagnece (%)

ExteIrniostraslilz4e-(ΦLx1W8 xH) (mm)

695 490 860

WTeoitgahlt (kg)
  High(kvVo)ltage Tarapnpgineg Low(vkoVl)tage              

30 50

       

80 100

630/600 910/870

1.5 1.3

   

260 365

                 

725

520

955  

63

        110

1090/1040

1.2

 

750

535

970

415

80

        130

1310/1250

1.2

 

770

565

985

465

100

        150

1580/1500

1.2

 

800

595

1000

545

125

      DYyynn101 Yzn11 170

1890/1800

1.1

 

815

670

1010

585

160

        200

2310/2200

1.1

4.0

1015

645

1055

695

200

66.3 61.06 1101.5

      240

2730/2600

1.0

 

1020

650

1115

810

250

        290

3200/3050

1.0

 

1140

730

1120

930

315

  ±±2x52.5

0.4

  340

3830/3650

0.9

 

1195

785

1175

1075

400

        410

4520/4300

0.9

 

1265

855

1195

1255

500

        480

5410/5100

0.8

 

1325

915

1240

1435

630

        570

6200

0.8

 

1465

960

1295

1880

800

       DYyynn101 700

7500

0.6

 4.5

1515

995

1340

2145

1000

        830

10300

0.6

 

1605

1095

1460

2455

1250

        970

12000

0.5

 

1685

1145

1485

2840

1600

        1170

14500

0.5

 

1775

1225

1580

3310

2000

        1550

18300

0.4

 

1855

1265

1600

3960

2500

        1830

21200

0.4

5.0

1885

1305

1780

4980

Note 1 : for transformers wlth rated capacity of 500kVA and below, the load loss values above the diagonal line in the table are applicable to the Dyn11 or Yzn11 coupling group,and the load loss values below the diagonal line are applicable to the Yyn0 coupling group.
Note 2: when the average annual load rate of the transformer is between 35% and 40%, the maximum operating efficiency can be obtained by using the loss value in the table.

Transformer Product Selection (89)

S14-M Technical Parameter

caRpaatecdity (kvA) Voltage combination Cognrnoeucpted label diNssoi-ploaatidon (w) dissLiopaadtion (W)75℃ Ncuor-rIoeandt (%) Imvpoeltdaagnece (%) ExteIrniostraslilz4e-(ΦLx1W8 xH) (mm) WTeoitgahlt (kg)
  High(kvVo)ltage Tarapnpgineg Low(vkoVl)tage              

30 50

       

80 100

505/480 730/695

1.5 1.3

  785×710×880 800×730×940

370 480

63

        110

870/830

1.2

  815×720×970

535

80

        130

1050/1000

1.2

  830×740×990

580

100

        150

1260/1200

1.1

  875×790×1010

705

125

      DYyynn101 Yzn11 170

1510/1440

1.1

  875×770×1050

775

160

        200

1850/1760

1.0

4.0

935×820×1140

975

200

66.3 61.06 1101.5

      240

2180/2080

1.0

  995×870×1140

1140

250

        290

2560/2440

0.9

  995×900×1180

1240

315

  ±±2x52.5

0.4

  340

3060/2920

0.9

  1030×880×1250

1425

400

        410

3610/3440

0.8

  1075×910×1270

1635

500

        480

4330/4120

0.8

  1120×930×1320

1950

630

        570

4960

0.6

  1165×950×1350

2150

800

       DYyynn101 700

6000

0.6

 4.5 1210×1050×1390

2515

1000

        830

8240

0.6

  1520×1020×1450

2635

1250

        970

9600

0.5

  1630×1090×1540

3210

1600

        1170

11600

0.5

  1680×1150×1600

3905

2000

        1550

14600

0.4

  1890×1300×1600

4130

2500

        1830

16900

0.4

5.0

1990×1360×1700

5250

Note 1 : for transformers wlth rated capacity of 500kVA and below, the load loss values above the diagonal line in the table are applicable to the Dyn11 or Yzn11 coupling group,and the load loss values below the diagonal line are applicable to the Yyn0 coupling group.
Note 2: when the average annual load rate of the transformer is between 35% and 40%, the maximum operating efficiency can be obtained by using the loss value in the table.

Transformer Product Selection (89)