We have now a hugely efficient team to deal with inquiries from buyers. Our goal is "100% client gratification by our solution high-quality, rate & our team service" and take pleasure in a great popularity among clients. With several factories, we will provide a wide assortment of Step Down Transformer, Strain Clamp, Outdoor Boundary Load Break Switch, "Making the Products and solutions of Superior Quality" may be the eternal target of our company. We make unremitting attempts to comprehend the objective of "We Will Often Preserve in Pace along with the Time".
ODM Outdoor Vacuum Circuit Breaker Manufacturers – CAL9-40AFD:Arc fault detection device AFDD with integrated RCBO – Changan Group Detail:

6KA RCBO CAL9-40 WITH AFDD CAL9-40AFD (1)

Technical Data

Electrical Features

Mode Electronic
Type

Rated current In

AC,A

6,10,16,20,25,32,40A

Poles 1P+N(Pole N could be On/Off)
Rated voltage Ue 240V~
Insulation voltage Ui 400V
Rated frequency 50Hz
Rated residual operating current(I△n) 10,30,100,300mA
Break time under I△n ≤0.1s
Rated breaking capacity 6,000A
Energy limiting class 3
Rated impulse withstand voltage(1.5/50) Uimp 4,000V
Dielectric test voltage at ind.Freq. for 1min 2kV
Pollution degree 2
Thermo-magnetic release characteristic B,C

Mechanical Features

Electrical life 4,000 Cycles
Mechanical lifeContact position indicator 10,000 CyclesYes
Protection degree IP20
Reference temperature for setting of thermal element 30℃
Ambient temperature (with daily average≤35℃) -5℃~+40℃
Storage temperature -25℃~+70℃

Installation

Terminal connection typeTerminal size top/bottom for cable Cable/Pin-type busbar16mm2 18-5AWG
Terminal size top/bottom for busbar 16mm2 18-5AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection Power supply from top

Characteristics

Tripping Current Range

Type

AC

Tripping current I△/A0.5I△n<I△<I△n
I△n>0.01A I△n≤0.01A

A

90°

135°

0.35I△n≤I△≤1.4I△n0.25I△n≤I△≤1.4I△n

0.11I△n≤I△≤1.4I△n

0.35I△n≤I△≤2I△n0.25I△n≤I△≤2I△n

0.11I△n≤I△≤2I△n

Characteristics Curves

6KA RCBO CAL9-40 WITH AFDD CAL9-40AFD (2)
6KA RCBO CAL9-40 WITH AFDD CAL9-40AFD (3)


Product detail pictures:

ODM Outdoor Vacuum Circuit Breaker Manufacturers –  CAL9-40AFD:Arc fault detection device AFDD with integrated RCBO – Changan Group detail pictures


Related Product Guide:

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for ODM Outdoor Vacuum Circuit Breaker Manufacturers – CAL9-40AFD:Arc fault detection device AFDD with integrated RCBO – Changan Group , The product will supply to all over the world, such as: Niger, Boston, Madrid, The working experience in the field has helped us forged a strong relations with customers and partners both in domestic and international market. For years, our products have been exported to more than 15 countries in the world and have been widely used by customers.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Jean from Rotterdam - 2018.09.16 11:31
    The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Judith from Malawi - 2017.10.23 10:29
    Write your message here and send it to us