ODM Outdoor Control Box Manufacturers – CS2 Series Motor Protection Circuit Breaker – Changan Group
ODM Outdoor Control Box Manufacturers – CS2 Series Motor Protection Circuit Breaker – Changan Group Detail:
Description
Electric value: AC690V, 32A, 80A;
Standard: IEC/EN 60947-2, IEC60947-4-1
Type Designation
Operating Condition
3.1 Temperature: -5 ℃~+40℃ ,average temperature in 24 hours not exceed +35 ℃
3.2 Altitude: not exceed 2000m
3.3 Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher
relative humidity is allowable under lower temperature,for example, RH could be 90% at +20℃
3.4 Pollution grade: Grade Ⅲ
3.5 Release grade: 10A(CS2-32) 10A(CS2-80)
3.6 Rated operational system: Continuous operational system
3.7 Mounting conditions:
The inclination between the mounting plane and the vertical plane shall not exceed 5 ° The product shall be installed and operated at a place without obvious shake, Impact and vibration.
Technical Specification
4.1 Protection property
Series No. | Multiple of setting current | Initial status | Time | Expected results | Ambient temperature | |
1 | 1.05 | Cold status | t≥2h | Non-tripping | +20℃±2℃ | |
2 | 1.20 | Heat status (right after test.1) | t<2h | Tripping | +20℃±2℃ | |
3 | 1.50 | Heat status (right after test.1) | Tripping class | 10A t<2min | Tripping | +20℃±2℃ |
10 t<4min | ||||||
4 | 7.20 | Cold status | Tripping class | 10A 2s<t≤10s | Tripping | +20℃±2℃ |
Phase failure protection properties
Series No. |
Multiple of setting current |
Initial status |
Time |
Expected results | Ambient temperature | |
Any 2 phase | The other phase | |||||
1 | 1.0 | 0.9 | Cold status |
t≥2h |
Non-tripping | +20℃±2℃ |
2 | 1.15 | 0 | Heat status
(right after test.1) |
t <2h |
Tripping | +20℃±2℃ |
Temperature compensation properties
Series No. | Multiple of setting current | Initial status | Time | Expected results | Ambient temperature |
1 | 1.0 | Cold status | t≥2h | Non-tripping |
+40℃±2℃ |
2 | 1.2 | Heat status (right after test.1) | t<2h | Tripping | +40℃±2℃ |
3 | 1.05 | Cold status | t≥2h | Non-tripping |
-5℃±2℃ |
4 | 1.3 | Heat status (right after test.3) | t<2h | Tripping | -5℃±2℃ |
Model of overload relay | Code | Rated current (A) | Rated ultimate short-circuit breaking capacity Icu(kA) | Rated service short-circuit breaking capacity Ics(kA) | Standard rated power of three-phase motor (kW) | ||||||
230/240V | 400/415V | 660/690V | 230/240V | 400/415V | 660/690V | 230/240V | 400/415V | 660/690V | |||
CS2-32 |
3201 |
0.1~0.16 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | - |
3202 |
0.16~0.25 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | - | |
3203 |
0.25~0.4 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | - | |
3204 |
0.4~0.63 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | 0.37 | |
3205 |
0.63~1 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | 0.55 | |
3206 |
1~1.6 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | 1.1 | |
3207 |
1.6~2.5 | 100 | 100 | 3 | 100 | 100 | 2.25 | 0.37 | 0.75 | 1.5 | |
3208 |
2.5~4 | 100 | 100 | 3 | 100 | 100 | 2.25 | 0.75 | 1.5 | 3 | |
3210 |
4~6.3 | 100 | 100 | 3 | 100 | 100 | 2.25 | 1.1 | 2.2 | 4 | |
3214 |
6~10 | 100 | 100 | 3 | 100 | 100 | 2.25 | 2.2 | 4 | 7.5 | |
3216 |
9~14 | 100 | 15 | 3 | 100 | 7.5 | 2.25 | 3 | 5.5 | 9 | |
3220 |
13~18 | 100 | 15 | 3 | 100 | 7.5 | 2.25 | 4 | 9 | 11 | |
3221 |
17~23 | 50 | 15 | 3 | 50 | 6 | 2.25 | 5.5 | 11 | 15 | |
3222 |
20~25 | 50 | 15 | 3 | 50 | 6 | 2.25 | 5.5 | 11 | 18.5 | |
3232 |
24~32 | 50 | 15 | 3 | 50 | 6 | 2.25 | 7.5 | 12.5 | 22 | |
CS2-80 |
8025 |
16~25 | - | 15 | - | - | 7.5 | - | 5.5 | 11 | - |
8040 |
25~40 | - | 15 | - | - | 7.5 | - | 11 | 22 | - | |
8063 |
40~63 | - | 15 | - | - | 7.5 | - | 15 | 33 | - | |
8080 |
56~80 | - | 15 | - | - | 7.5 | - | 22 | 45 | - |
Product detail pictures:
![ODM Outdoor Control Box Manufacturers – CS2 Series Motor Protection Circuit Breaker – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CS2-SERIES-MOTOR-PROTECTION-1.png)
![ODM Outdoor Control Box Manufacturers – CS2 Series Motor Protection Circuit Breaker – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CS2-SERIES-MOTOR-PROTECTION-2.png)
Related Product Guide:
High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for ODM Outdoor Control Box Manufacturers – CS2 Series Motor Protection Circuit Breaker – Changan Group , The product will supply to all over the world, such as: Turin, Bangalore, Mozambique, Honest to every customers are our requested! First-class serve, best quality, best price and fastest delivery date is our advantage! Give every customers good serve is our tenet! This makes our company get the favour of customers and support! Welcome all over the world customers send us enquiry and looking forward your good co-operation !Make sure you your inquiry for more details or request for dealership in selected regions.
![5 Stars](https://www.changan-electric.com/admin/img/star-icon.png)
The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!