ODM Fixed Type Switchgear Supplier – S □ -35kV Series Oil Immersed Power Transformer – Changan Group

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our concentrate on should be to consolidate and enhance the quality and service of present products, meanwhile consistently produce new products to meet unique customers' demands for Industrial Push Button, Control Power Transformer, Miniature Circuit Breaker, Sincerely hope we are growing up together with our prospects all over the environment.
ODM Fixed Type Switchgear Supplier – S □ -35kV Series Oil Immersed Power Transformer – Changan Group Detail:

Product introduction

S □ – 35kV series oil immersed transformer produced by the company is suitable for three-phase AC 50 / 60Hz, rated voltage 35kV distribution grid, and plays an important role in high-voltage transmission and low-voltage power supply. Products with high efficiency, low loss characteristics, can save a lot of power consumption and operating costs, social benefits, has been widely used in power plants, substations, industrial and mining enterprises, ports, airports and other places.
With on load tap changer, the product can realize the function of manual or automatic voltage regulation without power failure, which is conducive to stabilizing the voltage of power grid in each load center and improving the quality of power supply.

Model Meaning

Oil Immersed Power Transformer

Standards

GB/T 1094.1-2013 Power transformers – Part 1: General
GB/T 1094.2-2013 Power transformers – Part 2: Temperature rise for liquid-immersed transformers GB/T 1094.3-2017 Power transformers – Part 3:Insulation levels, dielectric tests and external clearances in air GB/T 1094.5-2008 Power transformers – Part 5: Ability to withstand short circuit
GB/T 1094.10-2003 Power transformers–Part 10: Determination of sound levels IEC60076-1:2011 Power transformers – Part 1: General
IEC60076-2:2011 Power transformers – Part 2: Temperature rise for liquid-immersed transformers
IEC 60076-3:2013+AMD1:2018 Power transformers – Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-5:2006 Power transformers – Part 5: Ability to withstand short circuit
IEC 60076-10:2016 Power transformers – Part 10: Determination of sound levels

Normal Environment conditions

1.Ambient Temperature: No more than +40℃ No less than -25℃ The monthly average temperature is no more than +30℃ The yearly average temperature is no more than +20℃
2.Altitude: No more than 1000m. 3.The power supply voltage’s wave is similar to sine wave. 4.Three-phase power supply voltage is approximately symmetrical.
5.The total harmonic content of load current shall not exceed 5% of ratedcurrent; 6.Installation Site: Indoor or outdoor.

Product characteristics

1.The core is made of cold-rolled silicon steel sheet with high magnetic conductivity and grain orientation, with low no-load loss.
2.The three-phase winding is concentric coil, corrugated oil duct, no paint dipping process and tight band binding are adopted. High mechanical strength, balanced ampere turn distribution, strong short circuit resistance.
3.The positioning structure is added to the body to avoid displacement during transportation. At the same time, all fasteners are equipped with fastening nuts to ensure that the fasteners are not loose during long-term operation.
4.This product is a fully sealed structure. The vacuum oil filling process is adopted when the transformer is packaged, which completely removes the moisture in the transformer, ensures the isolation of the transformer oil from the outside air, prevents the aging of the oil, and improves the operation reliability of the transformer. All transformers of capacity section are equipped with pressure relief valve, and gas relay with alarm and trip function can be installed according to user’s demand, which ensures the safe operation of transformer.
5.Corrugated oil tank is adopted. This kind of oil tank has the advantages of simple process, high mechanical strength, good welding effect and no leakage. And because of the strong fluidity of the oil, the heat dissipation capacity of the product is improved.
The product is beautiful in appearance, small in volume and small in floor area. It is an ideal maintenance free product

Transformer Product Selection (52)

S □ -35kV Technical Parameter

S13-35kV Technical parameters of non excitation voltage regulating transformer

50

3385.5

 ±2±×52.5  0.4  DYyynn101

160

1200/1140

1.3

 6.5

100

230

2010/1910

1.1

125

270

2370/2260

1.1

160

280

2820/2680

1.0

200

310

3320/3160

1.0

250

400

3950/3760

0.95

315

480

4750/4530

0.95

400

580

5740/5470

0.85

500

680

6910/6580

0.85

630

830

7860

0.65

800

980

9400

0.65

1000

1150

11500

0.65

1250

1400

13900

0.60

1600

1690

16600

0.60

2000

1990

19700

0.55

2500

2360

23200

0.55

caRpaatecdity (kvA) Voltage combination Cognrnoeucpted label diNssoi-ploaatidon (w) dissLiopaadtion (W)145℃ Ncuor-rIoeandt (%) Imvpoeltdaagnece (%)
 

High(kvVo)ltage

Tarapnpgineg

Low(vkoVl)tage          

630

       

830

7860

0.65

 

800

       

980

9400

0.65

 

1000

   

36.1.35 10.5

 

1150

11500

0.65

 

1250

35

±2±×52.5

   

1400

13900

0.55

6.5

1600

       

1690

16600

0.45

 

2000

     

Yd11

2170

18300

0.45

 

2500

       

2560

19600

0.45

 

3150

 35~38.5  ±2±×52.5  36.1.35 10.5  

3040

23000

0.45

 7.0

4000

       

3610

27300

0.45

 

5000

       

4320

31300

0.45

 

6300

       

5240

35000

0.45

 8.0

8000

 35~38.5  ±2×2.5  33.1.35 160..65  YNd11

7200

38100

0.35

 

10000

       

8700

45300

0.35

 

12500

       

10000

53800

0.3

 

16000

       

12100

65800

0.3

 

20000

       

14400

79500

0.3

 

25000

       

17000

94000

0.25

 10.0

31500

       

20200

112000

0.25

caRpaatecdity (kvA)

Voltage combination

High kvVo)ltage Taapping Low voltage

Cognrnoeucpted label diNssoi-ploaatidon (w) dissLiopaadtion (W)145℃ Ncuor-rIoeandt (%) Imvpoeltdaagnece (%)
 

r nge

(kV)

         

2000

        2300 19200

0.50

 
 

35

±3×2.5

160..35

       

6.5

2500

       

2720

20600

0.50

 

3150

 35~38.5  ±3×2.5

160..35

Yd11

3230

24700

o.50

 7.0

4000

       

3870

29100

0.50

 

5000

       

4640

34200

0.50

 

6300

       

5630

36700

0.50

 8.0

8000

 35~38.5  ±3×2.5 6.36 10.5 YNd11

7870

40600

0.40

 

10000

       

9280

48000

040

 

12500

       

1090

56800

0.35

 

16000

       

1310

70300

0.35

 

20000

       

1550

82100

0.35

 

25000

       

1830

97800

0.30

10.0

31500

       

2180

116000

0.30


Product detail pictures:

ODM Fixed Type Switchgear Supplier –  S □ -35kV Series Oil Immersed Power Transformer – Changan Group detail pictures


Related Product Guide:

Our commission would be to serve our customers and clientele with very best excellent and aggressive portable digital products for ODM Fixed Type Switchgear Supplier – S □ -35kV Series Oil Immersed Power Transformer – Changan Group , The product will supply to all over the world, such as: Venezuela, Macedonia, Croatia, Our staffs are adhering to the "Integrity-based and Interactive Development" spirit, and the tenet of "First-class Quality with Excellent Service". According to the needs of every customer, we give customized & personalised services to help customers achieve their goals successfully. Welcome clients from home and abroad to call and inquire!
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Athena from Comoros - 2018.09.21 11:44
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Gloria from Russia - 2018.09.19 18:37
    Write your message here and send it to us