ODM Emergency Stop Push Button Switch Suppliers – CC1 Series AC Contactor for 9-95A – Changan Group
ODM Emergency Stop Push Button Switch Suppliers – CC1 Series AC Contactor for 9-95A – Changan Group Detail:
Description
Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 95A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)
Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
Control Coil Voltage(DC Coil Operation)
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
Code |
JD |
BD |
CD |
ED |
FD |
MD |
Technical Specification
Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
Model No. |
CC1-09 |
CC1-12 |
CC1-18 |
CC1-25 |
CC1-32 |
|
Rated Conventional Heating Current |
Ith (A) |
20 |
20 |
32 |
40 |
50 |
Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
9 |
12 |
18 |
25 |
32 |
AC-4 Ie(A) |
3.5 |
5 |
7.7 |
8.5 |
12 |
|
Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
2.2 |
3 |
4 |
5.5 |
7.5 |
380/415V KW |
4 |
5.5 |
7.5 |
11 |
15 |
|
660/690V KW |
5.5 |
7.5 |
10 |
15 |
18.5 |
|
Electrial life(x103 operations) |
AC-3 |
1000 |
1000 |
1000 |
1000 |
800 |
AC-4 |
200 |
200 |
200 |
200 |
200 |
|
Mechanical life(x106 operations) |
10 |
10 |
10 |
10 |
8 |
|
Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
A |
20 |
20 |
32 |
40 |
50 |
|
Main circuit |
3P or 4P |
|||||
Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO or 1NC |
Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
Model No. |
CC1-40 |
CC1-50 |
CC1-65 |
CC1-80 |
CC1-95 |
|
Rated Conventional Heating Current |
Ith (A) |
60 |
80 |
80 |
100 |
125 |
Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
40 |
50 |
65 |
80 |
95 |
AC-4 Ie(A) |
18.5 |
24 |
28 |
37 |
44 |
|
Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
11 |
15 |
18.5 |
22 |
25 |
380/415V KW |
18.5 |
22 |
30 |
37 |
45 |
|
660/690V KW |
30 |
33 |
37 |
45 |
45 |
|
Electrial life(x103 operations) |
AC-3 |
800 |
600 |
600 |
600 |
600 |
AC-4 |
150 |
150 |
150 |
100 |
100 |
|
Mechanical life(x106 operations) |
8 |
8 |
8 |
6 |
6 |
|
Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
A |
63 |
80 |
80 |
100 |
125 |
|
Main circuit |
3P or 4P |
|||||
Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A |
1NO+1NC |
Model |
Cabling cross section(Cu) |
screw size | Tightening torque(N.m) | |||
Number of piece |
Flexible cable with cold-pressed socket(mm2 ) |
Flexible cable without cold- pressed socket(mm2 ) |
Inflexible cable(mm2 ) | |||
CC1-09 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
CC1-12 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
CC1-18 |
1~2 |
4 |
6 | 6 |
M3.5 |
0.8 |
CC1-25 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
CC1-32 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
CC1-40 |
1 |
10 |
16 | 10 |
M4 |
3.5 |
2 |
10 |
10 | 10 |
M8 |
3.5 |
|
CC1-50 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
2 |
16 |
16 | - |
M8 |
3.5 |
|
CC1-65 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
2 |
16 |
16 | - |
M8 |
3.5 |
|
CC1-80 |
1 |
50 |
50 | 50 |
M8 |
3.5 |
2 |
25 |
35 | - |
M10 |
4.0 |
|
CC1-95 |
1 |
50 |
50 | 50 |
M10 |
4.0 |
2 |
25 |
35 | - |
M10 |
4.0 |
1.L: in main circuit, the distance between terminals and plate;
2.P: in main circuit, the distance between two phases;
3.S: in main circuit, the width of contacting plate.
Model |
A max |
B max |
C max |
D max |
E max |
a |
b |
Φ |
L |
P |
S |
CC1-09(Z)~12(Z) |
47 |
76 |
82(116) |
120.5(154.5) |
140.5(174.5) |
34/35 |
50/60 |
4.5 |
60(95) |
10.5 |
8.6 |
CC1-18(Z) |
47 |
76 |
87(122) |
125.5(160.5) |
145.5(180.5) |
34/35 |
50/60 |
4.5 |
61(96) |
11.3 |
10.4 |
CC1-25(Z) |
57 |
86 |
95(131) |
133.5(169.5) |
153.5(189.5) |
40 |
48 |
4.5 |
70(107) |
13.2 |
11.7 |
CC1-32(Z) |
57 |
86 |
100(138) |
138.5(176.5) |
158.5(196.5) |
40 |
48 |
4.5 |
71.6(120) |
14.5 |
13 |
CC1-4011(Z)~6511(Z) |
77 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
CC1-4004/4008(Z)~6504/6508(Z) |
84 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
CC1-8011(Z)~9511(Z) |
87 |
129 |
127(188) |
165.5(226.5) |
185.5(246.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
CC1-8004/8008(Z)~9504/9508(Z) |
96 |
129 |
127(183) |
160.5(221.5) |
180.5(241.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
Product detail pictures:
Related Product Guide:
Adhering into the theory of "quality, services, efficiency and growth", now we have gained trusts and praises from domestic and international shopper for ODM Emergency Stop Push Button Switch Suppliers – CC1 Series AC Contactor for 9-95A – Changan Group , The product will supply to all over the world, such as: US, Algeria, Bolivia, Our company has built stable business relationships with many well-known domestic companies as well as oversea customers. With the goal of providing high quality products to customers at low cots, we've been committed to improving its capacities in research, development, manufacturing and management. We have honored to receive recognition from our customers. Till now we have now passed ISO9001 in 2005 and ISO/TS16949 in 2008. Enterprises of "quality of survival, the credibility of development" for the purpose, sincerely welcome domestic and foreign businessmen to visit to discuss cooperation.
By Madeline from Sudan - 2017.10.13 10:47
It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
By Arthur from Peru - 2018.09.08 17:09