We usually think and practice corresponding for the change of circumstance, and grow up. We aim at the achievement of a richer mind and body as well as the living for Insulated Wire Lugs, Motor Protection Circuit Breaker, Cable Jointing Lugs, We, with great passion and faithfulness, are willing to provide you with perfect services and striding forward with you to create a bright future.
ODM Earthing Materials Factories – CS2 Series Motor Protection Circuit Breaker – Changan Group Detail:

Description

Electric value: AC690V, 32A, 80A;
Standard: IEC/EN 60947-2, IEC60947-4-1

Type Designation

CS2 SERIES MOTOR PROTECTION  (3)

Operating Condition

3.1 Temperature: -5 ℃~+40℃ ,average temperature in 24 hours not exceed +35 ℃
3.2 Altitude: not exceed 2000m
3.3 Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher
relative humidity is allowable under lower temperature,for example, RH could be 90% at +20℃
3.4 Pollution grade: Grade Ⅲ
3.5 Release grade: 10A(CS2-32) 10A(CS2-80)
3.6 Rated operational system: Continuous operational system
3.7 Mounting conditions:
The inclination between the mounting plane and the vertical plane shall not exceed 5 ° The product shall be installed and operated at a place without obvious shake, Impact and vibration.

Technical Specification

4.1 Protection property

Series No. Multiple of setting current Initial status Time Expected results Ambient temperature
1 1.05 Cold status t≥2h Non-tripping +20℃±2℃
2 1.20 Heat status (right after test.1) t<2h Tripping +20℃±2℃
3 1.50 Heat status (right after test.1) Tripping class 10A t<2min Tripping +20℃±2℃
        10 t<4min    
4 7.20 Cold status Tripping class 10A 2s<t≤10s Tripping +20℃±2℃

Phase failure protection properties

 

Series No.

Multiple of setting current  

Initial status

 

Time

Expected results Ambient temperature
  Any 2 phase The other phase        
1 1.0 0.9 Cold status

t≥2h

Non-tripping +20℃±2℃
2 1.15 0 Heat status

(right after test.1)

t <2h

Tripping +20℃±2℃

Temperature compensation properties

Series No. Multiple of setting current Initial status Time Expected results Ambient temperature
1 1.0 Cold status t≥2h Non-tripping

+40℃±2℃

2 1.2 Heat status (right after test.1) t<2h Tripping  +40℃±2℃
3 1.05 Cold status t≥2h Non-tripping

-5℃±2℃

4 1.3 Heat status (right after test.3) t<2h Tripping  -5℃±2℃
Model of overload relay  Code Rated current (A) Rated ultimate short-circuit breaking capacity Icu(kA) Rated service short-circuit breaking capacity Ics(kA) Standard rated power of three-phase motor (kW)
      230/240V 400/415V 660/690V 230/240V 400/415V 660/690V 230/240V 400/415V 660/690V
CS2-32

3201

0.1~0.16 100 100 100 100 100 100 - - -
 

3202

0.16~0.25 100 100 100 100 100 100 - - -
 

3203

0.25~0.4 100 100 100 100 100 100 - - -
 

3204

0.4~0.63 100 100 100 100 100 100 - - 0.37
 

3205

0.63~1 100 100 100 100 100 100 - - 0.55
 

3206

1~1.6 100 100 100 100 100 100 - - 1.1
 

3207

1.6~2.5 100 100 3 100 100 2.25 0.37 0.75 1.5
 

3208

2.5~4 100 100 3 100 100 2.25 0.75 1.5 3
 

3210

4~6.3 100 100 3 100 100 2.25 1.1 2.2 4
 

3214

6~10 100 100 3 100 100 2.25 2.2 4 7.5
 

3216

9~14 100 15 3 100 7.5 2.25 3 5.5 9
 

3220

13~18 100 15 3 100 7.5 2.25 4 9 11
 

3221

17~23 50 15 3 50 6 2.25 5.5 11 15
 

3222

20~25 50 15 3 50 6 2.25 5.5 11 18.5
 

3232

24~32 50 15 3 50 6 2.25 7.5 12.5 22
 CS2-80

8025

16~25 - 15 - - 7.5 - 5.5 11 -
 

8040

25~40 - 15 - - 7.5 - 11 22 -
 

8063

40~63 - 15 - - 7.5 - 15 33 -
 

8080

56~80 - 15 - - 7.5 - 22 45 -

CS2 MPCB_01
CS2 MPCB_02


Product detail pictures:

ODM Earthing Materials Factories –  CS2 Series Motor Protection Circuit Breaker – Changan Group detail pictures

ODM Earthing Materials Factories –  CS2 Series Motor Protection Circuit Breaker – Changan Group detail pictures


Related Product Guide:

Our firm sticks on the theory of "Quality will be the life in the enterprise, and status could be the soul of it" for ODM Earthing Materials Factories – CS2 Series Motor Protection Circuit Breaker – Changan Group , The product will supply to all over the world, such as: Tunisia, Johannesburg, Rio de Janeiro, Our next goal is to exceed the expectations of every client by offering outstanding customer service, increased flexibility and greater value. All in all, without our customers we do not exist; without happy and fully satisfied customers, we fail. We are looking for the wholesale, Drop ship. Please contact us if you are interesting our products. Hope to do business with you all. High quality and fast shipment!
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Lilith from Borussia Dortmund - 2018.09.08 17:09
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Darlene from Malaysia - 2017.05.02 18:28
    Write your message here and send it to us