ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group
ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group Detail:
Description
Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 800A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1
Control Coil Voltage(AC Coil Operation)
Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
Control Coil Voltage(DC Coil Operation)
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
Code |
JD |
BD |
CD |
ED |
FD |
MD |
Technical Specification
Standard |
IEC/EN60947-4-1 |
||||||
Model No. |
CC1-115 |
CC1-150 |
CC1-185 |
CC1-225 |
CC1-265 |
CC1-330 |
|
Rated Conventional Heating Current |
Ith (A) |
200 |
200 |
275 |
275 |
315 |
380 |
Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
690 |
Rated Operation Current Ue=380/415V |
AC-3 Ie(A) |
115 |
150 |
185 |
225 |
265 |
330 |
AC-4 Ie(A) |
52 |
60 |
79 |
86 |
105 |
117 |
|
Power Controlled 3ph cage Motor AC-3 |
380/415V KW |
55 |
75 |
90 |
110 |
132 |
160 |
660/690V KW |
80 |
100 |
110 |
129 |
160 |
220 |
|
Electrial life (x103 operations) |
AC-3 |
600 |
600 |
300 |
300 |
300 |
300 |
AC-4 |
100 |
100 |
100 |
100 |
100 |
100 |
|
Mechanical life (x106 operations) |
6 |
6 |
3 |
3 |
3 |
3 |
|
Matched Fuse |
Size |
RT16-1 |
RT16-2 |
RT16-2 |
RT16-2 |
RT16-2 |
RT16-3 |
A |
200 |
225 |
315 |
315 |
355 |
450 |
|
Main circuit |
3P or 4P |
Standard |
IEC/EN60947-4-1 |
||||||
Model No. |
CC1-400 |
CC1-500 |
CC1-630 |
CC1-780 |
CC1-800 |
CC1-1000 |
|
Rated Conventional Heating Current |
Ith (A) |
460 |
580 |
850 |
1200 |
850 |
1200 |
Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
690 |
Rated Operation Current Ue=380/415V |
AC-3 Ie(A) |
400 |
500 |
630 |
780 |
800 |
1000 |
AC-4 Ie(A) |
138 |
147 |
188 |
240 |
195 |
320 |
|
Power Controlled 3ph cage Motor AC-3 |
380/415V KW |
200 |
250 |
335 |
400 |
400 |
500 |
660/690V KW |
280 |
335 |
450 |
475 |
475 |
560 |
|
Electrial life (x103 operations) |
AC-3 |
300 |
300 |
300 |
200 |
200 |
200 |
AC-4 |
100 |
100 |
100 |
50 |
50 |
50 |
|
Mechanical life (x106 operations)) |
3 |
3 |
3 |
2 |
3 |
2 |
|
Matched Fuse |
Size |
RT16-3 |
RT16-4 |
RT16-4 |
RT16-4 |
RT16-4 |
RT16-4 |
A |
500 |
630 |
800 |
1250 |
800 |
1250 |
|
Main circuit |
3P or 4P |
4. Terminal CModel | onnection
Cabling(Cu) |
Screw size | Tightening torque (N·m) | ||
Number of piece |
Cable Cross section(mm)2 |
Cu busbar Cross section(mm)2 | |||
CC1-115 |
1 |
70~90 |
- |
M6 |
3 |
CC1-150 |
1 |
70~90 |
- |
M8 |
6 |
CC1-185 |
1 |
95~150 |
- |
M8 |
6 |
CC1-225 |
1 |
95~150 |
- |
M10 |
10 |
CC1-265 |
1 |
120~185 |
- |
M10 |
10 |
CC1-330 |
1 |
185~240 |
- |
M10 |
10 |
CC1-400 |
1(2) |
240(150) |
30×5 |
M10 |
10 |
CC1-500 |
2 |
150~185 |
40×5 |
M10 |
10 |
CC1-630 |
2 |
185~240 |
50×5 |
M12 |
14 |
CC1-800 |
2 |
185~240 |
50×5 |
M12 |
14 |
Model |
A max |
B max |
C max |
CC1-115 |
163.5 |
162 |
171 |
CC1-150 |
163.5 |
170 |
171 |
CC1-185 |
168.5 |
174 |
181 |
CC1-225 |
168.5 |
197 |
181 |
CC1-265 |
201.5 |
203 |
213 |
CC1-330 |
213 |
206 |
219 |
CC1-400 |
213 |
206 |
219 |
CC1-500 |
233 |
238 |
232 |
CC1-630/800 |
309 |
304 |
255 |
Product detail pictures:
![ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CC1-400.jpg)
![ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CC1-225.jpg)
![ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CC1-630.jpg)
![ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CC1-780.jpg)
Related Product Guide:
We have been also concentrating on enhancing the things management and QC method so that we could preserve terrific edge inside the fiercely-competitive enterprise for ODM Dual Circuit Breaker Supplier – CC1 Series AC Contactor for 115-1000A – Changan Group , The product will supply to all over the world, such as: Mali, Naples, Slovakia, Excellent quality comes from our adherence to every detail, and customer satisfaction comes from our sincere dedication. Relying on advanced technology and industry reputation of good cooperation, we try our best to provide more quality products and services to our customers, and all of us are willing to strengthen exchanges with domestic and foreign customers and sincere cooperation, to build a better future.
![5 Stars](https://www.changan-electric.com/admin/img/star-icon.png)
Problems can be quickly and effectively resolved, it is worth to be trust and working together.
![5 Stars](https://www.changan-electric.com/admin/img/star-icon.png)