"Sincerity, Innovation, Rigorousness, and Efficiency" would be the persistent conception of our corporation to the long-term to establish collectively with customers for mutual reciprocity and mutual benefit for Power Distribution Assemblies, Power Distribution, Three Phase Motor Starter, We acquire high-quality as the foundation of our results. Thus, we focus over the manufacture on the finest top quality goods. A strict quality management system has been created to guarantee the caliber of the merchandise.
ODM Covered Emergency Stop Button Manufacturers – CR2 Series Thermal Overload Relay – Changan Group Detail:

Description

Electric value: AC 50/60Hz, 690V, 0.1A~630A; Tripping class: 10A;
Mounting version:
a.Plug-in: Available for CR2-03,13,23,33,43;
b.Independent: Available for CR2-53, 63; Standard: IEC/EN 60947-4-1

Type Designation

product

Feature

3.1 3-phase bimetal
3.2Continuously readjustable current settings
3.3Temperature compensation
3.4Tripping indicator
3.5Test button
3.6Stop button
3.7Manual and automatic reset button
Electrically separated 1N/O plus 1N/C contact

Technical Specification

Item

Series No.

I/In

Operating time Tp

Test condition
Overload protection  1  1.05  >2 h  Start from cold status

2

1.2

≤2h

Start from heat status, right after item No.1

3

1.5

≤2min

Start from heat status, right after item No.1
 4  7.2  2s<Tp≤10s  Startfromcoldstatus
Phase failure protection  5 Any two phases Another phase  >2 h  Start from cold status

1.0

0.9

6

1.15

0

≤2 h

Start from heat status, right after item No.5

product1

Assembly with contactor

Model of overload relay Code Rated current (A) Recommended fuse type (RT16 is recommended) Contactor Matched

aM

gG

 

 

 

CR2-03

0301

0.1~0.16

0.25

2

 

 

 

CC1-09K CC1-12K

0302

0.16~0.25

0.5

2

0303

0.25~0.4

1

2

0304

0.4~0.63

1

2

0305

0.63~1

2

4

0306

1~1.6

2

4

0307

1.6~2.5

4

6

0308

2.5~4

6

10

0310

4~6

8

16

0312

5.5~8

12

20

0314

7~10

12

20

0316

9~13

16

25

 

 

 

 

 

CR2-13

1301

0.1~0.16

0.25

2

 

 

 

 

CC1-09 CC1-12 CC1-18 CC1-25 CC1-32

1302

0.16~0.25

0.5

2

1303

0.25~0.4

1

2

1304

0.4~0.63

1

2

1305

0.63~1

2

4

1306

1~1.6

2

4

1307

1.6~2.5

4

6

1308

2.5~4

6

10

1310

4~6

8

16

1312

5.5~8

12

20

1314

7~10

12

20

1316

9~13

16

25

1321

12~18

20

35

1322

17~25

25

50

CR2-23

2353

23~32

40

63

CC1-32

2355

30~40

40

80

 

CR2-33

3353

23~32

40

63

CC1-40 CC1-50 CC1-65 CC1-80 CC1-95

3355

30~40

40

100

3357

37~50

63

100

3359

48~65

63

100

3361

55~70

80

125

3363

63~80

80

125

3365

80~93

100

160

CR2-43

4366

80~104

125

200

CC1-115 CC1-150

4367

95~120

125

224

4368

110~150

160

250

CR2-53

5369

80~125

125

200

CC1-115 CC1-185 CC1-150 CC1-225

5370

100~160

160

250

5371

125~200

200

315

 

CR2-63

6372

160~250

250

400

CC1-185 CC1-400 CC1-225 CC1-500 CC1-265 CC1-630 CC1-330

6373

200~315

315

500

6374

250~400

400

630

6375

315~500

500

800

6376

400~630

630

800

C series Industrial Controls_16
C series Industrial Controls_17


Product detail pictures:

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures

ODM Covered Emergency Stop Button Manufacturers –  CR2 Series Thermal Overload Relay – Changan Group detail pictures


Related Product Guide:

To constantly improve the management system by virtue of the rule of "sincerely, good faith and quality are the base of enterprise development", we widely absorb the essence of related products internationally, and constantly develop new products to meet the demands of customers for ODM Covered Emergency Stop Button Manufacturers – CR2 Series Thermal Overload Relay – Changan Group , The product will supply to all over the world, such as: Latvia, Vancouver, Moscow, Our company is an international supplier on this kind of merchandise. We offer an amazing selection of high-quality products. Our goal is to delight you with our distinctive collection of mindful products while providing value and excellent service. Our mission is simple: To provide the best products and service to our customers at the lowest prices possible.
  • Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Naomi from Suriname - 2018.09.29 13:24
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Althea from Marseille - 2017.02.14 13:19
    Write your message here and send it to us