Our merchandise are broadly identified and trusted by end users and can satisfy continually developing economic and social requires for Single Phase Fuse Box, Fuse Trip Switch, Leakage Circuit Breaker, Our company is dedicated to providing customers with high and stable quality products at competitive price, making every customer satisfied with our products and services.
ODM Contactor Relay Supplier – CS2 Series Motor Protection Circuit Breaker – Changan Group Detail:

Description

Electric value: AC690V, 32A, 80A;
Standard: IEC/EN 60947-2, IEC60947-4-1

Type Designation

CS2 SERIES MOTOR PROTECTION  (3)

Operating Condition

3.1 Temperature: -5 ℃~+40℃ ,average temperature in 24 hours not exceed +35 ℃
3.2 Altitude: not exceed 2000m
3.3 Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher
relative humidity is allowable under lower temperature,for example, RH could be 90% at +20℃
3.4 Pollution grade: Grade Ⅲ
3.5 Release grade: 10A(CS2-32) 10A(CS2-80)
3.6 Rated operational system: Continuous operational system
3.7 Mounting conditions:
The inclination between the mounting plane and the vertical plane shall not exceed 5 ° The product shall be installed and operated at a place without obvious shake, Impact and vibration.

Technical Specification

4.1 Protection property

Series No. Multiple of setting current Initial status Time Expected results Ambient temperature
1 1.05 Cold status t≥2h Non-tripping +20℃±2℃
2 1.20 Heat status (right after test.1) t<2h Tripping +20℃±2℃
3 1.50 Heat status (right after test.1) Tripping class 10A t<2min Tripping +20℃±2℃
        10 t<4min    
4 7.20 Cold status Tripping class 10A 2s<t≤10s Tripping +20℃±2℃

Phase failure protection properties

 

Series No.

Multiple of setting current  

Initial status

 

Time

Expected results Ambient temperature
  Any 2 phase The other phase        
1 1.0 0.9 Cold status

t≥2h

Non-tripping +20℃±2℃
2 1.15 0 Heat status

(right after test.1)

t <2h

Tripping +20℃±2℃

Temperature compensation properties

Series No. Multiple of setting current Initial status Time Expected results Ambient temperature
1 1.0 Cold status t≥2h Non-tripping

+40℃±2℃

2 1.2 Heat status (right after test.1) t<2h Tripping  +40℃±2℃
3 1.05 Cold status t≥2h Non-tripping

-5℃±2℃

4 1.3 Heat status (right after test.3) t<2h Tripping  -5℃±2℃
Model of overload relay  Code Rated current (A) Rated ultimate short-circuit breaking capacity Icu(kA) Rated service short-circuit breaking capacity Ics(kA) Standard rated power of three-phase motor (kW)
      230/240V 400/415V 660/690V 230/240V 400/415V 660/690V 230/240V 400/415V 660/690V
CS2-32

3201

0.1~0.16 100 100 100 100 100 100 - - -
 

3202

0.16~0.25 100 100 100 100 100 100 - - -
 

3203

0.25~0.4 100 100 100 100 100 100 - - -
 

3204

0.4~0.63 100 100 100 100 100 100 - - 0.37
 

3205

0.63~1 100 100 100 100 100 100 - - 0.55
 

3206

1~1.6 100 100 100 100 100 100 - - 1.1
 

3207

1.6~2.5 100 100 3 100 100 2.25 0.37 0.75 1.5
 

3208

2.5~4 100 100 3 100 100 2.25 0.75 1.5 3
 

3210

4~6.3 100 100 3 100 100 2.25 1.1 2.2 4
 

3214

6~10 100 100 3 100 100 2.25 2.2 4 7.5
 

3216

9~14 100 15 3 100 7.5 2.25 3 5.5 9
 

3220

13~18 100 15 3 100 7.5 2.25 4 9 11
 

3221

17~23 50 15 3 50 6 2.25 5.5 11 15
 

3222

20~25 50 15 3 50 6 2.25 5.5 11 18.5
 

3232

24~32 50 15 3 50 6 2.25 7.5 12.5 22
 CS2-80

8025

16~25 - 15 - - 7.5 - 5.5 11 -
 

8040

25~40 - 15 - - 7.5 - 11 22 -
 

8063

40~63 - 15 - - 7.5 - 15 33 -
 

8080

56~80 - 15 - - 7.5 - 22 45 -

CS2 MPCB_01
CS2 MPCB_02


Product detail pictures:

ODM Contactor Relay Supplier –  CS2 Series Motor Protection Circuit Breaker – Changan Group detail pictures

ODM Contactor Relay Supplier –  CS2 Series Motor Protection Circuit Breaker – Changan Group detail pictures


Related Product Guide:

We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for ODM Contactor Relay Supplier – CS2 Series Motor Protection Circuit Breaker – Changan Group , The product will supply to all over the world, such as: Portland, Italy, Nairobi, We are introduced as a one of the growing manufacture supplier and export of our products. We have a team of dedicated trained professional who take care the quality and timely supply. If you are looking for Good Quality at a good price and timely delivery. Do contact us.
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Olivia from Tunisia - 2017.11.01 17:04
    The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Annie from Moscow - 2017.03.28 12:22
    Write your message here and send it to us