Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group
Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group Detail:
Description
Electric value: AC 50/60Hz, 690V, 0.1A~630A; Tripping class: 10A;
Mounting version:
a.Plug-in: Available for CR2-03,13,23,33,43;
b.Independent: Available for CR2-53, 63; Standard: IEC/EN 60947-4-1
Type Designation
Feature
3.1 3-phase bimetal
3.2Continuously readjustable current settings
3.3Temperature compensation
3.4Tripping indicator
3.5Test button
3.6Stop button
3.7Manual and automatic reset button
Electrically separated 1N/O plus 1N/C contact
Technical Specification
Item |
Series No. |
I/In |
Operating time Tp |
Test condition | |
Overload protection | 1 | 1.05 | >2 h | Start from cold status | |
2 |
1.2 |
≤2h |
Start from heat status, right after item No.1 | ||
3 |
1.5 |
≤2min |
Start from heat status, right after item No.1 | ||
4 | 7.2 | 2s<Tp≤10s | Startfromcoldstatus | ||
Phase failure protection | 5 | Any two phases | Another phase | >2 h | Start from cold status |
1.0 |
0.9 |
||||
6 |
1.15 |
0 |
≤2 h |
Start from heat status, right after item No.5 |
Assembly with contactor
Model of overload relay | Code | Rated current (A) | Recommended fuse type (RT16 is recommended) | Contactor Matched | |
aM |
gG |
||||
CR2-03 |
0301 |
0.1~0.16 |
0.25 |
2 |
CC1-09K CC1-12K |
0302 |
0.16~0.25 |
0.5 |
2 |
||
0303 |
0.25~0.4 |
1 |
2 |
||
0304 |
0.4~0.63 |
1 |
2 |
||
0305 |
0.63~1 |
2 |
4 |
||
0306 |
1~1.6 |
2 |
4 |
||
0307 |
1.6~2.5 |
4 |
6 |
||
0308 |
2.5~4 |
6 |
10 |
||
0310 |
4~6 |
8 |
16 |
||
0312 |
5.5~8 |
12 |
20 |
||
0314 |
7~10 |
12 |
20 |
||
0316 |
9~13 |
16 |
25 |
||
CR2-13 |
1301 |
0.1~0.16 |
0.25 |
2 |
CC1-09 CC1-12 CC1-18 CC1-25 CC1-32 |
1302 |
0.16~0.25 |
0.5 |
2 |
||
1303 |
0.25~0.4 |
1 |
2 |
||
1304 |
0.4~0.63 |
1 |
2 |
||
1305 |
0.63~1 |
2 |
4 |
||
1306 |
1~1.6 |
2 |
4 |
||
1307 |
1.6~2.5 |
4 |
6 |
||
1308 |
2.5~4 |
6 |
10 |
||
1310 |
4~6 |
8 |
16 |
||
1312 |
5.5~8 |
12 |
20 |
||
1314 |
7~10 |
12 |
20 |
||
1316 |
9~13 |
16 |
25 |
||
1321 |
12~18 |
20 |
35 |
||
1322 |
17~25 |
25 |
50 |
||
CR2-23 |
2353 |
23~32 |
40 |
63 |
CC1-32 |
2355 |
30~40 |
40 |
80 |
||
CR2-33 |
3353 |
23~32 |
40 |
63 |
CC1-40 CC1-50 CC1-65 CC1-80 CC1-95 |
3355 |
30~40 |
40 |
100 |
||
3357 |
37~50 |
63 |
100 |
||
3359 |
48~65 |
63 |
100 |
||
3361 |
55~70 |
80 |
125 |
||
3363 |
63~80 |
80 |
125 |
||
3365 |
80~93 |
100 |
160 |
||
CR2-43 |
4366 |
80~104 |
125 |
200 |
CC1-115 CC1-150 |
4367 |
95~120 |
125 |
224 |
||
4368 |
110~150 |
160 |
250 |
||
CR2-53 |
5369 |
80~125 |
125 |
200 |
CC1-115 CC1-185 CC1-150 CC1-225 |
5370 |
100~160 |
160 |
250 |
||
5371 |
125~200 |
200 |
315 |
||
CR2-63 |
6372 |
160~250 |
250 |
400 |
CC1-185 CC1-400 CC1-225 CC1-500 CC1-265 CC1-630 CC1-330 |
6373 |
200~315 |
315 |
500 |
||
6374 |
250~400 |
400 |
630 |
||
6375 |
315~500 |
500 |
800 |
||
6376 |
400~630 |
630 |
800 |
Product detail pictures:
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-03.png)
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-13.png)
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-23.png)
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-33.png)
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-43.png)
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-53.png)
![Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group detail pictures](https://cdn.globalso.com/changan-electric/CR2-63.png)
Related Product Guide:
To constantly improve the management system by virtue of the rule of "sincerely, good faith and quality are the base of enterprise development", we widely absorb the essence of related products internationally, and constantly develop new products to meet the demands of customers for Famous Voltage And Current Meter Suppliers – CR2 Series Thermal Overload Relay – Changan Group , The product will supply to all over the world, such as: Paris, Jamaica, Brasilia, Our products have been obtained more and more recognition from foreign clients, and established long term and cooperative relationship with them. We`ll provide the best service for every customer and sincerely welcome friends to work with us and establish the mutual benefit together.
![5 Stars](https://www.changan-electric.com/admin/img/star-icon.png)
The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
![5 Stars](https://www.changan-electric.com/admin/img/star-icon.png)