Famous Leakage Circuit Breaker Factory – CC1 Series Mini Contactor for 9-12A – Changan Group
Famous Leakage Circuit Breaker Factory – CC1 Series Mini Contactor for 9-12A – Changan Group Detail:
Description
Application: remote making & breaking circuits; protect circuit
from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 12A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)
Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
Control Coil Voltage(DC Coil Operation)
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
Code |
JD |
BD |
CD |
ED |
FD |
MD |
Technical Specification
Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||
Model No. |
CC1-06E |
CC1-09K |
CC1-12K |
|
Rated Conventional Heating Current |
Ith (A) |
16 |
20 |
20 |
Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
6 |
9 |
12 |
AC-4 Ie(A) |
1.5 |
3.5 |
5 |
|
Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
2.2 |
2.2 |
3 |
380/415V KW |
3 |
4 |
5.5 |
|
660/690V KW |
5.5 |
5.5 |
7.5 |
|
Electrial life(x103 operations) |
AC-3 |
1000 |
1000 |
1000 |
AC-4 |
200 |
200 |
200 |
|
Mechanical life(x106 operations)) |
10 |
10 |
10 |
|
Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
A |
20 |
20 |
20 |
|
Main circuit |
3P or 4P |
|||
Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A |
1NO or 1NC |
Product detail pictures:
Related Product Guide:
Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for Famous Leakage Circuit Breaker Factory – CC1 Series Mini Contactor for 9-12A – Changan Group , The product will supply to all over the world, such as: British, Curacao, France, Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective products and meticulous after-sales service. We firmly believe that: we are outstanding as we are specialized.
By Laura from Macedonia - 2018.11.22 12:28
This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
By Myra from Johannesburg - 2018.09.08 17:09