Famous Adjustable Circuit Breaker Supplier – CS2 Series Motor Protection Circuit Breaker – Changan Group Detail:
Description
Electric value: AC690V, 32A, 80A;
Standard: IEC/EN 60947-2, IEC60947-4-1
Type Designation
Operating Condition
3.1 Temperature: -5 ℃~+40℃ ,average temperature in 24 hours not exceed +35 ℃
3.2 Altitude: not exceed 2000m
3.3 Air conditions:
At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher
relative humidity is allowable under lower temperature,for example, RH could be 90% at +20℃
3.4 Pollution grade: Grade Ⅲ
3.5 Release grade: 10A(CS2-32) 10A(CS2-80)
3.6 Rated operational system: Continuous operational system
3.7 Mounting conditions:
The inclination between the mounting plane and the vertical plane shall not exceed 5 ° The product shall be installed and operated at a place without obvious shake, Impact and vibration.
Technical Specification
4.1 Protection property
Series No. | Multiple of setting current | Initial status | Time | Expected results | Ambient temperature | |
1 | 1.05 | Cold status | t≥2h | Non-tripping | +20℃±2℃ | |
2 | 1.20 | Heat status (right after test.1) | t<2h | Tripping | +20℃±2℃ | |
3 | 1.50 | Heat status (right after test.1) | Tripping class | 10A t<2min | Tripping | +20℃±2℃ |
10 t<4min | ||||||
4 | 7.20 | Cold status | Tripping class | 10A 2s<t≤10s | Tripping | +20℃±2℃ |
Phase failure protection properties
Series No. |
Multiple of setting current |
Initial status |
Time |
Expected results | Ambient temperature | |
Any 2 phase | The other phase | |||||
1 | 1.0 | 0.9 | Cold status |
t≥2h |
Non-tripping | +20℃±2℃ |
2 | 1.15 | 0 | Heat status
(right after test.1) |
t <2h |
Tripping | +20℃±2℃ |
Temperature compensation properties
Series No. | Multiple of setting current | Initial status | Time | Expected results | Ambient temperature |
1 | 1.0 | Cold status | t≥2h | Non-tripping |
+40℃±2℃ |
2 | 1.2 | Heat status (right after test.1) | t<2h | Tripping | +40℃±2℃ |
3 | 1.05 | Cold status | t≥2h | Non-tripping |
-5℃±2℃ |
4 | 1.3 | Heat status (right after test.3) | t<2h | Tripping | -5℃±2℃ |
Model of overload relay | Code | Rated current (A) | Rated ultimate short-circuit breaking capacity Icu(kA) | Rated service short-circuit breaking capacity Ics(kA) | Standard rated power of three-phase motor (kW) | ||||||
230/240V | 400/415V | 660/690V | 230/240V | 400/415V | 660/690V | 230/240V | 400/415V | 660/690V | |||
CS2-32 |
3201 |
0.1~0.16 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | - |
3202 |
0.16~0.25 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | - | |
3203 |
0.25~0.4 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | - | |
3204 |
0.4~0.63 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | 0.37 | |
3205 |
0.63~1 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | 0.55 | |
3206 |
1~1.6 | 100 | 100 | 100 | 100 | 100 | 100 | - | - | 1.1 | |
3207 |
1.6~2.5 | 100 | 100 | 3 | 100 | 100 | 2.25 | 0.37 | 0.75 | 1.5 | |
3208 |
2.5~4 | 100 | 100 | 3 | 100 | 100 | 2.25 | 0.75 | 1.5 | 3 | |
3210 |
4~6.3 | 100 | 100 | 3 | 100 | 100 | 2.25 | 1.1 | 2.2 | 4 | |
3214 |
6~10 | 100 | 100 | 3 | 100 | 100 | 2.25 | 2.2 | 4 | 7.5 | |
3216 |
9~14 | 100 | 15 | 3 | 100 | 7.5 | 2.25 | 3 | 5.5 | 9 | |
3220 |
13~18 | 100 | 15 | 3 | 100 | 7.5 | 2.25 | 4 | 9 | 11 | |
3221 |
17~23 | 50 | 15 | 3 | 50 | 6 | 2.25 | 5.5 | 11 | 15 | |
3222 |
20~25 | 50 | 15 | 3 | 50 | 6 | 2.25 | 5.5 | 11 | 18.5 | |
3232 |
24~32 | 50 | 15 | 3 | 50 | 6 | 2.25 | 7.5 | 12.5 | 22 | |
CS2-80 |
8025 |
16~25 | - | 15 | - | - | 7.5 | - | 5.5 | 11 | - |
8040 |
25~40 | - | 15 | - | - | 7.5 | - | 11 | 22 | - | |
8063 |
40~63 | - | 15 | - | - | 7.5 | - | 15 | 33 | - | |
8080 |
56~80 | - | 15 | - | - | 7.5 | - | 22 | 45 | - |
Product detail pictures:
Related Product Guide:
We have our own product sales staff, style crew, technical group, QC staff and package staff. We now have strict high quality management procedures for each approach. Also, all of our workers are experienced in printing subject for Famous Adjustable Circuit Breaker Supplier – CS2 Series Motor Protection Circuit Breaker – Changan Group , The product will supply to all over the world, such as: Mauritius, Benin, Belgium, We believe with our consistently excellent service you can get the best performance and cost least goods from us for a long term . We commit to provide better services and create more value to all our customers. Hope we can create a better future together.
By Brook from Egypt - 2018.08.12 12:27
We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.